<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Užití elektrické energie Archivy - Studijni-svet.cz</title>
	<atom:link href="https://studijni-svet.cz/tag/uziti-elektricke-energie/feed/" rel="self" type="application/rss+xml" />
	<link>https://studijni-svet.cz/tag/uziti-elektricke-energie/</link>
	<description>Studijní materiály do školy a k maturitě</description>
	<lastBuildDate>Mon, 20 Sep 2021 16:28:21 +0000</lastBuildDate>
	<language>cs</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://studijni-svet.cz/wp-content/uploads/2024/08/apple-touch-icon-150x150.png</url>
	<title>Užití elektrické energie Archivy - Studijni-svet.cz</title>
	<link>https://studijni-svet.cz/tag/uziti-elektricke-energie/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Součásti volných vedení (stožáry)</title>
		<link>https://studijni-svet.cz/soucasti-volnych-vedeni-stozary/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 01 Jun 2021 23:38:34 +0000</pubDate>
				<category><![CDATA[Fyzika a elektro]]></category>
		<category><![CDATA[Užití elektrické energie]]></category>
		<guid isPermaLink="false">https://studijni-svet.cz/?p=21250</guid>

					<description><![CDATA[<p>&#160; Otázka: Součásti volných vedení (stožáry) Předmět: Užití elektrické energie Přidal(a): hanny &#160; &#160; Mechanika vedení Elektrické sítě a) kabelové b) venkovní &#160; Venkovní vedení a) vodiče b) izolátory c) stožáry d) základny &#160; Návrh elektrického vedení Výchozím podkladem pro mechanický návrh elektrického vedení je výpočet zavěšeného vodiče, který určuje rozmístění stožárů podél trasy i ... <a title="Součásti volných vedení (stožáry)" class="read-more" href="https://studijni-svet.cz/soucasti-volnych-vedeni-stozary/" aria-label="Číst více o Součásti volných vedení (stožáry)">Read more</a></p>
<p>Článek <a href="https://studijni-svet.cz/soucasti-volnych-vedeni-stozary/">Součásti volných vedení (stožáry)</a> se nejdříve objevil na <a href="https://studijni-svet.cz">Studijni-svet.cz</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignleft" src="http://www.studijni-svet.cz/wp-content/uploads/ICONS/PREDMETY/Ostatni.png" alt="elektro" /></p>
<p>&nbsp;</p>
<p><strong>Otázka:</strong> Součásti volných vedení (stožáry)</p>
<p><strong>Předmět:</strong> Užití elektrické energie</p>
<p><strong>Přidal(a):</strong> hanny</p>
<p>&nbsp;</p>
<p><span id="more-21250"></span></p>
<p>&nbsp;</p>
<h2><strong>Mechanika vedení</strong></h2>
<p><strong>Elektrické sítě</strong></p>
<ul>
<li>a) kabelové</li>
<li>b) venkovní</li>
</ul>
<p>&nbsp;</p>
<p><strong>Venkovní vedení</strong></p>
<ul>
<li>a) vodiče</li>
<li>b) izolátory</li>
<li>c) stožáry</li>
<li>d) základny</li>
</ul>
<p>&nbsp;</p>
<p><strong>Návrh elektrického vedení</strong></p>
<ul>
<li>Výchozím podkladem pro mechanický návrh elektrického vedení je výpočet zavěšeného vodiče, který určuje rozmístění stožárů podél trasy i dimenzování ostatních prvků venkovního vedení</li>
<li>Maximální vzdálenost mezi stožáry je 600 m</li>
<li>Elektrická vedení se navrhují a staví zhruba s 50letou životností (životnost stožáru 50-70 let a vedení 25-50 let)</li>
</ul>
<p>&nbsp;</p>
<p><strong>Materiály vodičů</strong></p>
<ul>
<li><strong>Vodiče</strong></li>
<li style="list-style-type: none;">
<ul>
<li>Měď (Cu)</li>
<li>Hliník (Al)</li>
<li>Slitiny hliníku</li>
<li>Ocel</li>
<li>Pro speciální účely (bronz, slitiny mědi</li>
</ul>
</li>
<li><strong>Dráty do 1 kV</strong></li>
<li style="list-style-type: none;">
<ul>
<li>Měď</li>
<li>Hliník</li>
<li>Železo</li>
</ul>
</li>
<li><strong>Lana prostá</strong></li>
<li style="list-style-type: none;">
<ul>
<li>Hliník</li>
<li>Bronz</li>
<li>Železo</li>
</ul>
</li>
<li><strong>Lana kombinovaná</strong></li>
<li style="list-style-type: none;">
<ul>
<li>Hliník</li>
<li>Železo</li>
</ul>
</li>
<li><strong>Svazkové vodiče</strong></li>
<li><strong>Závěsné kabely</strong></li>
<li style="list-style-type: none;">
<ul>
<li>Vodič</li>
<li>Izolant</li>
<li>Nosné lano</li>
</ul>
</li>
</ul>
<p><strong> </strong></p>
<p><strong>Nejmenší dovolené průřezy lan na venkovním vedení</strong></p>
<table width="427">
<tbody>
<tr>
<td width="103">Materiál</td>
<td width="164">do 1kV</td>
<td width="160">10-35kV</td>
</tr>
<tr>
<td width="103">Cu &#8211; tvrdá</td>
<td width="164">6</td>
<td width="160">10</td>
</tr>
<tr>
<td width="103">Cu &#8211; polotvrdá</td>
<td width="164">6</td>
<td width="160">0</td>
</tr>
<tr>
<td width="103">Al</td>
<td width="164">16</td>
<td width="160">25</td>
</tr>
<tr>
<td width="103">Fe</td>
<td width="164">10</td>
<td width="160">16</td>
</tr>
<tr>
<td width="103">LANO ALFE</td>
<td width="164">16</td>
<td width="160">16</td>
</tr>
<tr>
<td width="103">LANO AldFe</td>
<td width="164">16</td>
<td width="160">16</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p><strong>Vzdálenosti vodičů</strong></p>
<p>a) Od země (na místech volně přístupných)</p>
<table width="397">
<tbody>
<tr>
<td width="237">Druh vedení</td>
<td width="160">Vzdálenost (m)</td>
</tr>
<tr>
<td width="237">do 1kV</td>
<td width="160">5</td>
</tr>
<tr>
<td width="237">do 1kV (nad zemědělskými plochami)</td>
<td width="160">6</td>
</tr>
<tr>
<td width="237">10-110kV</td>
<td width="160">6</td>
</tr>
<tr>
<td width="237">220kV</td>
<td width="160">7</td>
</tr>
<tr>
<td width="237">400kV</td>
<td width="160">8</td>
</tr>
</tbody>
</table>
<p>b) Od nosné konstrukce – do 1kV minimálně 10 cm</p>
<p>c) Mezi sebou minimálně 20 cm</p>
<table width="580">
<tbody>
<tr>
<td width="123"></td>
<td width="64">nejmenší</td>
<td width="73">vzdálenost</td>
<td width="64">od</td>
<td width="64">vodiče</td>
<td width="64">s</td>
<td width="64">napětím</td>
<td width="64">(cm)</td>
</tr>
<tr>
<td width="123">Napětí (kV)</td>
<td width="64">do 1kV</td>
<td width="73">1 &#8211; 10kV</td>
<td width="64">22kV</td>
<td width="64">35kV</td>
<td width="64">110kV</td>
<td width="64">220kV</td>
<td width="64">400kV</td>
</tr>
<tr>
<td width="123">do 1kV</td>
<td width="64">20</td>
<td width="73">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">1 až 10kV</td>
<td width="64">32</td>
<td width="73">22</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">22kV</td>
<td width="64">40</td>
<td width="73">30</td>
<td width="64">30</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">35kV</td>
<td width="64">50</td>
<td width="73">40</td>
<td width="64">40</td>
<td width="64">40</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">110kV</td>
<td width="64">0</td>
<td width="73">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">90</td>
<td width="64">0</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">220kV</td>
<td width="64">0</td>
<td width="73">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">190</td>
<td width="64">190</td>
<td width="64">0</td>
</tr>
<tr>
<td width="123">400kV</td>
<td width="64">0</td>
<td width="73">0</td>
<td width="64">0</td>
<td width="64">0</td>
<td width="64">340</td>
<td width="64">340</td>
<td width="64">340</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h2><strong>Venkovní vedení</strong></h2>
<p><strong>Výzbroj vodičů (spojování vodičů)</strong></p>
<ul>
<li>kroucení</li>
<li>vazy</li>
<li>spojky trubkové, vrubové a šroubové</li>
</ul>
<p>&nbsp;</p>
<p><strong>K výzbroji patří:</strong></p>
<ul>
<li>rozpěrky svazkových vodičů</li>
<li>tlumiče</li>
</ul>
<p>&nbsp;</p>
<p><strong>Izolátory:</strong></p>
<ul>
<li>podpěrné do 35kV</li>
<li>závěsné od 22kV</li>
<li>tyčové</li>
<li>talířové</li>
</ul>
<p>&nbsp;</p>
<p><strong>Materiály izolátorů:</strong></p>
<ul>
<li>tvrdý porcelán, sklo, plast + sklo, gumové povrchy</li>
</ul>
<p>&nbsp;</p>
<p><strong>Upevnění vodičů:</strong></p>
<ul>
<li>vazem</li>
<li>svorkou</li>
</ul>
<p>&nbsp;</p>
<p><strong>Výhody závěsných izolátorů:</strong></p>
<ul>
<li>vyrovnávají tahy sousedních polí</li>
<li>při přetržení vodiče odlehčují stožár</li>
<li>větší bezpečnost proti průrazům</li>
<li>snadnější montáž a skladování</li>
</ul>
<p>&nbsp;</p>
<h2><strong>Stožáry</strong></h2>
<p><strong>Rozdělení podle účelu:</strong></p>
<ul>
<li>N – nosné</li>
<li>R – rohový</li>
<li>V – výstužný</li>
<li>RV – složený rohový/výstužný</li>
<li>O – odbočný</li>
<li>OV – složený odbočný/výstužný</li>
<li>Ko – koncový</li>
<li>KN – složený koncový/nosný</li>
<li>KV – složený koncový/výstužný</li>
<li>KRV – složený koncový/rohový/výstužný</li>
<li>K – křižovatkový</li>
</ul>
<p>&nbsp;</p>
<p><strong>Výstužné stožáry:</strong></p>
<ul>
<li>minimálně co 3 km =&gt; jednoduchý vodič</li>
<li>5 km =&gt; svazkový vodič</li>
</ul>
<p>&nbsp;</p>
<p><strong>Materiál stožárů: </strong></p>
<ul>
<li>dřevo, ocel, beton, železo-beton</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Při výpočtu (výběr stožáru) se uvažuje:</strong></p>
<ul>
<li>normální stav</li>
<li>tlak větru na vodiče a stožár</li>
<li>tahy ve vodičích</li>
<li>námraza</li>
<li>vlastní hmotnost stožáru, vodiče a armatury</li>
<li>výslednice sil při zalomení a odbočení</li>
<li>momenty sil při přetržení vodiče</li>
</ul>
<p>&nbsp;</p>
<p><strong>Dřevěné stožáry:</strong></p>
<ul>
<li>Skupina 1 – smrk, jedle, borovice</li>
<li>Skupina 2 – modřín, buk, dub</li>
</ul>
<p>&nbsp;</p>
<p><strong>Tipy:</strong></p>
<ul>
<li>Jednoduchý (J)</li>
<li>Složené (dvojsloup)</li>
</ul>
<p>&nbsp;</p>
<p><strong>Základ:</strong></p>
<ul>
<li>Do země minimálně 150 cm</li>
<li>Hmotná ochrana proti hnilobě (penetrací)</li>
</ul>
<p>&nbsp;</p>
<p><strong>Ocelové stožáry:</strong></p>
<ul>
<li>Příhradové</li>
<li>Trubkové</li>
</ul>
<p>&nbsp;</p>
<p><strong>Části stožáru:</strong></p>
<ul>
<li>Dřík</li>
<li>Hlava</li>
<li>Konzola</li>
<li>Držák zemnícího lana</li>
</ul>
<p>&nbsp;</p>
<p><strong>Typy stožárů:</strong></p>
<ul>
<li>Kočka</li>
<li>Dunaj</li>
<li>Soudek</li>
<li>Delta</li>
<li>Vertikál (Čenda)</li>
<li>Portál</li>
</ul>
<p>&nbsp;</p>
<p><strong>Ochrana proti korozi:</strong></p>
<ul>
<li>Barva</li>
<li>Pozinkování</li>
<li>Atmofix</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Na stožárech se může vyskytnout další zařízení</strong></p>
<ul>
<li>a) úsekové vypínače</li>
<li>b) pojistky</li>
<li>c) bleskojistky</li>
<li>d) transformátory</li>
<li>e) kondenzátory</li>
<li>f) rozvaděče</li>
</ul>
<p>&nbsp;</p>
<p><strong>Stabilita</strong> = stupeň bezpečnosti připojení</p>
<ul>
<li>uložení stožáru
<ul>
<li>=&gt; do 13 m do vykopaných jam</li>
<li>=&gt;14 m a více – železobetonový základ</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p><strong>Značení vedení</strong></p>
<ul>
<li>Po levé straně liché číslo (barva bílá)</li>
<li>Po pravé straně sudé číslo (barva červená)</li>
<li>Odbočky (barva modrá)</li>
</ul>
<p>&nbsp;</p>
<p><strong>Kroucení vedení VVN </strong>(transpozice)</p>
<ul>
<li><u>Transpozice</u> &#8211; aby vlivem rozdílných indukčních vodičů nedošlo k nesymetrii napětí na konci vedení provádí se na vedení VVN tzv. zákrut</li>
<li>V místě zákrutu se provede vystřídání vodiče v hlavě stožáru</li>
<li>Zákrutem se dosáhne toho, že indukčnost každé fáze je přibližně stejná</li>
<li>Jeden zákrut se provádí do 200km délky vedení, na 300 km vedení pak provede plný zákrut</li>
</ul>
<p>&nbsp;</p>
<p><strong>Hloubky uložení kabelu do země</strong></p>
<table width="320">
<tbody>
<tr>
<td width="112"><strong>napětí</strong></td>
<td width="70"><strong>terén</strong></td>
<td width="70"><strong>chodník</strong></td>
<td width="70"><strong>vozovka</strong></td>
</tr>
<tr>
<td width="112">do 1kV</td>
<td width="70">35 cm</td>
<td width="70">35 cm</td>
<td width="70">100 cm</td>
</tr>
<tr>
<td width="112">do 10kV</td>
<td width="70">70 cm</td>
<td width="70">50 cm</td>
<td width="70">100 cm</td>
</tr>
<tr>
<td width="112">do 35kV</td>
<td width="70">100 cm</td>
<td width="70">100 cm</td>
<td width="70">100 cm</td>
</tr>
<tr>
<td width="112">do 110kV</td>
<td width="70">130 cm</td>
<td width="70">130 cm</td>
<td width="70">130 cm</td>
</tr>
</tbody>
</table>
<p>Ochrana před mechanickým poškozením =&gt; krytí cihlami, tvárnicemi, dlaždicemi</p>
<p>Kabely do 1kV se mohou klást bez mechanické ochrany a musí být označeny výstražnou fólií</p>
<p>Článek <a href="https://studijni-svet.cz/soucasti-volnych-vedeni-stozary/">Součásti volných vedení (stožáry)</a> se nejdříve objevil na <a href="https://studijni-svet.cz">Studijni-svet.cz</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
